HOME/OFFICE MODEM
2. <automode>=an optional numeric value which enables or
disables automatic modulation negotiation. Options are:
<automode>
Option Selected
0 Automode disabled
1 Automode enabled
The default value is 1, which enables automode. Note,
however, there are modulations for which there is no automatic
negotiation (e.g., Bell 212 (<mod>=69).
For <automode> = 0 (automode disabled, i.e., fixed
modulation):
a. If <max_rate> is within the rates supported by the selected
modulation, the selected rate is that specified by <max_rate>.
Example: +MS=9,0,1200,4800 selects V.32 4800bps fixed rate.
b. If <max_rate> is greater than the highest speed supported by
the modulation specified by <mod>, the starting rate is the
highest rate supported by the selected modulation.
Example: +MS=9,0,2400,14400 selects V.32 9600 or 4800bps.
c. To emulate N0S37=x command sequence to select fixed mode
operation, specify the <max_rate> and <min_rate> both to be
the same requested speed, and <mod> to be the modulation
for that speed.